Vendor Settings dialog
[彫刻] > [彫刻のデフォルト] > [セットアップ] > [彫刻機のオプション]タブ > [機械設定]の順にクリックします。
Vendor Settings
Machine Type |
Select a machine type. Note: Recommended setting is Normal. |
Transmission Mode |
カットの種類を選択します。 |
Feed Mode | Select a direction. |
Broken Delay | In case of an interruption, set to allow adjustment time for the controller position to minimize gaps. |
Z Function | |
Enable Protection | Enable to prevent machine operation when the lid is open. |
Enable Blower | |
Head Distance | In a dual-headed machine, the distance between heads. |
Laser Settings
Laser Configuration | Select the number of lasers. |
Laser Mode | Select the tube type. |
Laser Attenuation | As the power increases from zero, set to move the head more slowly. |
Show laser supply info | |
Laser 1, 2 | |
Min Power (%) | |
Max Power (%) | |
Laser Frequency (KHz) |
The frequency for the tube. |
PreIgnition Frequency Hz) | For RF tubes with pre-ignition. |
PreIgnition Pulse (%) | For RF tubes with pre-ignition. |
Signal Level | For glass tubes set input level. |
Water Protection | Select if using a water flow sensor. |
モーションカード設定
X, Y, Z, U | Select axis. |
Direction Polarity | Based on machine origin, set for direction of movement. |
Limiter Polarity |
Set according to the limit switch direction when triggered
|
Breadth | Total area of movement. |
Home Offset | The distance between the limit switch and 0. |
Control Mode | Set according to motor drivers. |
Enable Limit Trigger | Enable limit switch protection. |
PWM Rising Edge Valid | Set based on the effective edge of the motor driver pulse. |
Auto Homing | Enabling moves the laser head to home position on start up. |
Jump-off Speed | The initial speed of the head on the axis. |
Max Speed | |
Step Length |
To ensure the scale is correct, set the size of each step. For example, a 1" square comes out as a 1" square. Note: The recommendation is to do an initial test with a set size and compare the output, then adjust if necessary. |
Max Acc | Set maximum acceleration rate. |
Estop Acc | If the emergency stop is triggered, set the acceleration rate. |
Jump-off Speed | The initial speed of the head on the axis when operated from the control panel. |
Accel | Acceleration from start speed to operating speed when operated from the control panel. |
反転の選択 | Select to reverse the movement of the axis when the LCD key is pressed on the control panel. |