Note: These materials are offered only in English as supplementary examples for a deeper dive into
Connecting Cutters and Plotters to SignLab
If your cutter or plotter is connected by a Serial or Parallel port, or if you are unsure what connection to use, watch the following video:
USB -> USB Connection
All devices connected with a standard USB cable require a USB Port driver from the manufacturer.
If you do not install these drivers, the plotter will not work from any software.
In-app plotter drivers are installed either during the initial software installation or from File > Install > Cutting devices.
Graphtec Plotters
Before installing drivers for your plotter, check that there is a USB Port driver available from Graphtec that is compatible with your operating system.
You can check and download from here: Graphtec Cutting Plotters
If there is no driver for your plotter and operating system combination, you will need to find an alternative connection solution.
Once you have installed the correct driver for your plotter in
The port to select is:
- Graphtec{Model}_USB001+
- External Dll
- Fiery Graphtec USB
An “Error Opening Output Pipe” when you try to plot means the cutter is not connected or the Graphtec USB port does not exist and the USB port drivers still need to be installed.
Summa Plotters
Check that there is a USB Port driver installed from Summa.
You can check and download from here: Vinyl Cutter Downloads
The file needed is USB Cutter driver.
The driver you install from
Once you have installed the driver for your plotter in
The port to select is:
- External DLL
An “Error Opening Output Pipe” when you try to plot means the cutter is not connected or the Summa USB port does not exist and the USB port drivers still need to be installed.
Roland Plotters
Before installing drivers for your plotter in-app, check that there is a USB Port driver available from Roland that is compatible with your operating system.
You can check and download from here: Cutting
If there is no driver for your plotter and operating System combination, you will need to find an alternative connection solution.
Once you have installed the correct driver for your plotter in
The port to select here is :
- Roland{Model}_USB001+
If you do not see the port Roland{model}_USB001+ or similar then the USB port drivers are not installed or the cutter is not connected.
Mimaki Plotters
Before installing drivers for your plotter in
You can check and download from here: Cutting Plotter
The file needed will be Mimaki Driver.
Once you have installed the correct driver for your plotter in
The port to select here is External Dll or Fiery Mimaki USB.
If a connection to the cutter is found, the cutter name will change to CG-FX-00 or similar. If this does not happen, no connection is made.
Other Plotters
Some manufacturers (Mutoh, GCC, and many others) use a Standard USB cable, but when connected to the PC and Plotter, a Virtual Serial Port is created in Windows.
Once you have installed the correct driver for your plotter in
The port to select with these cutters is usually named something like USB => Serial (ComX). You might also see UnknownPrinter_USB001+ or similar.